Fixing DRC failures
Diagnose and fix the DRC failures you'll meet most often, from a missing interface pair to protocol, role, voltage and capacity mismatches
Goal
Recognize the common DRC failures by their reasons and fix each one. Each section names the reason text you'll see in Board Review.
The fix loop
No interface link (grey, BLOCKED)
Reason: No interface link
The harness exists but carries nothing. Select it and choose an Interface pair under Interface selection. See Harnesses and function links.
No compatible pair (red, BLOCKED)
Reason: No compatible interface pairs found
The two parts have no interfaces that can connect, for example a battery wired straight to a motor. Connect through the part that sits between them (a motor driver, regulator, level shifter or converter), or swap one part for one with the interface you need.
Protocol mismatch (red, BLOCKED)
Reason: Protocol type mismatch: i2c vs spi
You paired two different protocols. Pick another pair: many sensors offer both I2C and SPI, so choose the same protocol on both sides.
Role conflict (red, BLOCKED)
Reason: Incompatible protocol roles: master cannot connect to master
Both sides have the same role. The reason lists the valid pairs for that protocol. Pick an interface with the complementary role. If a library part has the wrong role, report a problem with the part; on your own part, edit its template.
Voltage mismatch (red, BLOCKED)
Reason: Voltage ranges don't overlap: 4.5-5.5V vs 1.8-3.6V
For power, put a regulator between the two parts: source to regulator input, regulator output to the load.
For logic signals, put a level shifter between the 5 V side and the 3.3 V side.
Use a supply output at the right voltage (many boards have a 3.3 V pin), or swap to a breakout with on-board regulation.
Domain mismatch (red, BLOCKED)
Reason: Domain mismatch: electrical vs pneumatic
You paired interfaces from different physical domains. Pick a pair in the same domain.
Missing pins (yellow, PARTIAL)
Reason: Side A function 'i2c_sda' not yet assigned to a resource (0/1)
The function has no pin. Click Auto Assign in Function Links, or choose a pin in its resource picker. If no pin is offered, the part has run out: see Resource allocation.
Unwired functions (yellow, PARTIAL)
A required function on one side has no function link. Open Function Links and link it, or click Auto Assign. For fan-out harnesses, every instance needs its own links.
Over capacity (yellow, PARTIAL, plus a blocking part issue)
Reason: Interface '...' is over capacity
The part has more instances of an interface than its resources can back, for example three motors on a two-channel driver. Remove an instance, add a second driver or expander, or use a part with more channels.
One-sided link (yellow, PARTIAL)
Reason: One-sided link: only side A has an interface
The other part has no interface modelled. That's fine while you plan. To finish it, add the interface to that part's template, or replace it with a library part.
Quick reference
Grey harness
Choose an interface pair
Red, no compatible pair
Connect through an intermediate part
Red, protocol or role
Choose a different pair
Red, voltage
Regulator, level shifter or a different supply pin
Yellow, not assigned
Auto Assign, or pick pins
Yellow, over capacity
Fewer instances or a bigger part
Related pages