How DRC works
What the design rule check (DRC) checks, the four harness states, and how results show on the canvas and in Board Review
Goal
Understand what Protoboard's design rule check (DRC) looks at, what each result means and where you see it.
When DRC runs
DRC runs continuously. Every change to a part, harness or allocation updates the results within a moment. There's no button to press, and the same board always gives the same result.
What DRC checks
For each harness:
Is there an interface link? A harness with no interface pair is not configured.
Are the two interfaces compatible? Protocol type, roles, domain, electrical ranges (for example voltage ranges that don't overlap) and physical connector, when the part definitions specify them.
Is every required function wired? Each function the interface requires needs a function link on the harness.
Does every function have a resource? Each required function needs a pin or port allocated on its part.
Is each interface within capacity? A part can't carry more instances of an interface than its resources can back.
Optional functions don't need to be wired. With fan-out, every instance on the fanned side needs its own wiring and pins.
The four states
Configured
Green
All required functions are linked and allocated
(no issue)
Partially configured
Yellow
The interface link exists, but wiring or pins are missing, or an interface is over capacity
PARTIAL
Not configured
Grey
No interface link yet
BLOCKED
Incompatible
Red
The interfaces can't connect, or the parts share no compatible pair
BLOCKED
A one-sided link, where only one side has an interface because the other part isn't modelled yet, shows as partially configured. That's acceptable while you design; model the other side to reach Configured.
Over-capacity interfaces are also reported as blocking part issues.
Where you see results
On the canvas: each harness is coloured by its state.
In Board Review: open Board Review in the left rail. Issues are listed under // DRC Issues, grouped as BLOCKED and PARTIAL, each with its reasons and a target icon that shows it on the canvas. See Board Review and review comments.
For agents: ProtoBot and MCP agents run the same check with
run_drc.

Reading the reasons
Each issue lists why the harness isn't configured, for example:
No interface linkNo compatible interface pairs foundProtocol type mismatch: i2c vs spiVoltage ranges don't overlap: 4.5-5.5V vs 1.8-3.6VSide A function 'i2c_sda' not yet assigned to a resource (0/1)
Some reasons confirm what does match (for example Matching domain: electrical); they're context, not problems. For fixes, see Fixing DRC failures. The full list is in DRC rules and severity.
What DRC doesn't check
DRC works from the part definitions on your board. It doesn't simulate circuits, check timing or bus loading, or catch a wrong value in a part definition. Check critical numbers against the datasheet, and report a problem if a library part is wrong.